Manual Euro-MERiDIAN
Chapter 10 Page 10 - 13
(x) PLUG-ON RELAY
INTERFACE
This interface may be plugged onto Euro-44+ (or 134/256) End
Stations, and Output Modules.
Programme the outputs as follows:
Output If on End Station If on Output Module
Relay 1 (V 1
-
3) STU output 1 Output 1
Relay 2 (V 4
-
6) STU Output 2 Output 2
Relay 3 (V 7
-
9) STU output 3 Output 3
Relay 4 (V 10
-
12) STU Output 4 Output 4
Relay 5 (V 13
-
15) STU output 5 Output 5
Relay 6 (V 16
-
18) STU Output 6 Output 6
Strobe Output (R) STU Output 9 Output 7
Siren outputs (S) STU Output 10 Output 8
NOTE: Care must be taken to ensure that this PCB is plugged on
correctly – use the pin numbers as a guide.
If Site Option "Digi-Reply" is set to 'Relay' the Siren and Strobe
outputs on the relay PCB will be monitored in accordance with German
specifications!
Terminal Allocations
R STROBE
1 Strobe
2 Strobe +
S SIREN
1 Siren A
2 Siren A +
3 Siren B
4 Siren B +
V RELAYS
1 Relay 1 C
2 Relay 1 NO
3 Relay 1 NC
Repeat for relays
2
-