Page 14 - 4 Chapter 14
Soak Control?
Press YES
Soak Zones [---]
Insert number of zone
required to be on soak, eg
023, followed by YES
Soak Zones [---]
Zone 023
Repeat for additional zones to
be placed on soak, noting that
all zones selected will scroll.
To remove a zone from the
'soak list' simply insert this
number again and press YES.
On completion of selection,
press NO
Soak Days Left
[00]
This shows the number of
days currently left on the soak
timer. Change to number of
days soak is to apply, eg 14,
and press YES
Initial Soak
[14]
This is the number of days
that the soak timer will revert
to in the event of a soak zone
being triggered. Adjust as
required and press YES
Soak Control?
Press NO
Test Siren?
Press YES to activate test
–
ALL
outputs programmed to any
Siren OR STROBE output
configurations will trigger.
Testing Siren
...
Press NO
Do Batt Load
Test?
Battery Test
permits the
system batteries to be tested
Press YES to activate test
–
power supply voltage will
drop to place system load
onto battery. Results will be
displayed in the form
Testing Battery
12.5v 1.1A
Press NO
Do Batt Load
Test?
Press NO
Test Outputs?
Outputs Tests
permit the
system outputs to be tested
Press YES
Output Test [ ]
Use
A
and
B
or number keys
to select output type
required, from table on page
13
-
27, eg
‘
014 [Siren Any]
’
Press YES
Output Test [014]
Siren Any
Press YES