Castle Care-Tech Ltd. Engineering
Page 14 - 6 Chapter 14
Press
A
to make all siren and
strobe outputs live, so that
display shows alarm current.
Press
0
to return to
quiescent state.
Press YES
ZEM PSU [0]
13.65v 0.15A
Insert number of alternative
Zone Expander with PSU
fitted, and repeat above, as
required
Or: Press NO
Op Mod PSU [0]
13.65v 0.15A
Repeat steps described above
for Output Modules with PSUs
fitted
Press NO
Keypad volts [0]
13.70v
Displays system voltage at
indicated Keypad. Use number
key to change to alternative
Keypad
Press YES
Reader volts [0]
13.60v
Displays system voltage at
indicated Tag Reader. Use
number key to change to
alternative Reader
Press YES
View PSUs?
Press NO
View Zones?
Press YES
EndStation Zones?
Press YES
CccOOccOccOccOc
OOcccFFFFFFFFFF
Display shows status of zones 1
30 (End Station iD zones) in
real time, displaying the
following codes:
c: zone in normal state
0: zone in active state
F: zone in Tamper state
T: iD zone in
Twin Device
state
Press YES
CccOOF
Display shows status of zones
31
36 (End Station EoL zones)
in real time.
Press YES
Zone [001][01]
14mA 14mA iD
Display shows
diagnostic
current, and
switch
current
respectively for system zone
001, biscuit 01.
OR:
Zone [031][1]
2K2 EOL
Display shows circuit
resistance reading for system
zone 031, EoL zone 1
Press YES
Slow Scan?
Note: This option only
relevant if system includes iD
zones.
Press YES