Manual Euro-MERiDIAN
Chapter 9 Page 9 - 9
e) Additional Facilities
Additional facilities are
available for use in conjunction
with Sequential Confirmation
signalling, as follows:
(i) 'Entry Shock' zone type:
Patent applied for.
This zone type is always used in
conjunction with a 'Final Exit'
zone. The 'FX' zone is a door
contact on the initial entry
door, and the 'Entry Shock'
zone is a non-latching shock
sensor fitted to the door frame
in the vicinity of the lock.
If the initial entry door is
subject to gross attack and
forced open, then at the expiry
of entry time only one further
intruder zone needs to be
tripped to signal a sequentially
confirmed alarm - counting the
'Entry Shock' zone as the first
to alarm..
Triggering the Entry Shock
zone in isolation will NOT
generate an alarm of any kind.
The Final Exit door contact
must be opened within 10
seconds of the shock detector
triggering for the Entry Shock
response to apply.
This configuration thus
provides enhanced protection
for forced entry via the entry
route as an alternative to the
'shunt lock' option.
CAUTION:
The 'Entry Shock' function should
only be used after careful risk
assessment. It is essential that
the shock detector is properly
adjusted, and that the door
construction / fittings are
adequate for the purpose.
(ii) 'Confirm Group' zone
attribute
Applying this attribute to any
zone will prevent a zone from
confirming an alarm triggered
by another zone within the
same group.
Thus if a number of detectors
are in use that could respond
to the same stimulus (eg
multiple shock or pressure
wave detectors), these may be
wired individually to the
control to avoid the need for
complex 'series' wiring.
NOTE: Default allocation "00"
means that zone is NOT allocated
to a group.
Zones allocated to Group "99" will
trigger a first (unconfirmed) alarm
in the normal way, but will NEVER
trigger a 'confirmed' signal,
regardless of which group the
'first alarm' zone is allocated to.