Manual Euro-MERiDIAN
Chapter 9 Page 9 - 3
arm Isolates (in SITE OPTIONS)
is selected, in which case the
zone will remain isolated until
manually reset (unless it is a
Final Exit zone).
Misoperation (Abort)
Signalling
May be signalled:
A: By dedicated
Misoperation signal
B: By generation of the
unset signal
All these options will be
signalled (if programmed) when
a valid user code is entered
after the generation of the
intruder signal. There is no
time limit on this.
Note that 'intruder' signal will
restore if the system is reinstated
after an unconfirmed alarm.
Misoperation can optionally
be signalled when silencing an
alarm at a Ward Controller.
Engineer Reset
Separately programmable for
PA’‘Intruder,’'Confirmed' and
Tamper alarms, also for soak
zones triggering falsely. If
programmed, this becomes
valid immediately the
appropriate alarm output has
been generated.
NOTE: If audio or visual
confirmation systems are in use,
'engineer reset at confirmation'
will apply only when sequential
confirmation is valid.
Reset may be performed:
A: By use of the Engineer
code (even if another
area remains set)
B: By use of the Red Care
reset facility (see below).
C: By use of a remote reset
code generated at the
ARC from an anticode
generated by the system.
D: By download from Euro-
InSite software.
Engineer Reset of Intruder may
be selected as operative when
using standard Intruder
output signalling, or for Secure
Intruder signalling.
Digi Reply Signal
An input is available through
the STU connections to accept
an input signal from the Alarm
Receiving Centre.
This may be programmed (in
SITE OPTIONS) as:
None when not to be used.
Fail to Communicate' for
use with a digital
communicator (to log
the failure to receive
acknowledgement of
the signal from ARC).
Red Care Reset to accept an
Engineer Reset signal
from the ARC.
Relay provides monitoring
of the plug-on relay
interface (non-UK use).
NOTE: If 'None' or 'Relay' is
selected, monitoring of the inputs
will NOT be active.