Chapter 13 Page 13 - 13
(vi) ASSIGNING KEYPADS
and TAG READERS
NOTE: All keypads and Tag
Readers MUST be correctly
addressed before attempting
to program them in this menu.
See page 12-3.
Each setting point can be
programmed:
SETS
which security
pattern(s) can be Set
from it. Limits
operation to these
areas, regardless of
availability of code
used. Euro-10/12/22/28
can select any ONE level
as alternative to All
system.
UNSETS
which areas can be
Unset from it. Limits
operation to these
areas, regardless of
availability of code
used. Not applicable to
level-setting systems.
IN
-
which area(s) it is
located in.
Defines operation on
exit and entry, as
described on page 5
-
3.
NOT APPLICABLE TO
LEVEL SETTING SYSTEMS.
Care should be taken to
ensure that every area that
can be set, or to which a
zone is allocated, can be
unset by at least one Keypad
or Set/Unset Tag Reader.
Tag Readers can further be
selected as:
Access Control or Guard Tour
points (Euro-44+ and above) –
see Chapters 18 and 19
or
‘Ward Controllers’ –Chapter 16.
PROGRAMMING A KEYPAD:
With the display showing
ASSIGN KEYPADS/
READERS?
Press YES
Address
[0]
Use number keys (or
D
) to
select address
Press YES
Type
Keypad [0]
Use
D
to select
Keypad [0]
or
Reader [1]
Select [2] to DISABLE
Press YES
If Euro-10/12/22/28
Default Level?
[A ]
Select System Level that
will be set when code/tag
used at this set point
If Euro-44
Set Point Sets
Areas [ABCD]
Press appropriate key(s) to
select the areas (or a single
level) required, eg Press
A
Set Point Sets
Areas [A ]
Vista de pagina 99