Castle Care-Tech Ltd. Engineering
Page 6 - 2 Chapter 6
d) Backlighting
LCDs and Keypad keys are
backlit. The backlighting will
illuminate at the start of entry
and exit times, and at key (or
tag) entry, and will remain lit
for 30 seconds after the last key
entry, or termination of the
function.
NOTE: An option is available at each
keypad to force the backlight to remain
lit except in mains failure, see 12.3.
e) Fault Indications
Fault indications shown on the
Liquid Crystal Display will
include a numeric
identification of the individual
device at which the fault is
present, eg
Mains Failure 401
Device Failure 214 etc.
The first digit identifies the
device type:
1 = End Station
2 = Keypad
3 = Tag Reader
4 = Zone Expansion Module
5 = Output Module
The remaining digit(s) identify
the individual device of the
type, thus
Mains Failure 401 - identifies
the Zone Expansion
Module addressed as 01
etc.
For details of other fault
indications, see Appendix A.
f) Engineer Reset
If the system indicates
‘Engineer Reset Required’ (see
‘Site Options’), this must be
performed before the area(s)
on the system to which it
applies can be used again. The
reset may be performed:
a) By entering the engineer
code. The system will not
enter the engineer mode,
but will reset.
b) By entering the special
reset code derived from
the displayed ‘anticode,’ by
means of the Castle
Remote
Reset Code
’ programme.
c) By the ‘RedCare Reset’ line
being activated via a ‘STU’
d) By ‘Download Reset’ from a
PC running Euro-InSite
software.
The system will log the reset,
however initiated.
The entire system must be
unset before an Engineer Reset
may be performed.
Note: by default, engineer reset of
Intruder alarms will be invoked
when an intruder/confirmation
signal is triggered after the
system is set. If ‘secure intruder’
signals are used (which signal also
during exit time), a Site Option is
available to invoke Engineer Reset
in this mode also.