Manual Euro-MERiDIAN
Chapter 14 Page 14 - 5
Testing
Siren Any
ALL outputs programmed to
that
type
will become live,
INCLUDING those on slot
-
in Digi
and plug
-
on STU.
Press NO
Output Type [ ]
Output(s) switches off.
Repeat as above for other
output types, or
Press NO
Test Outputs?
Press NO
Test CHC
Communications?
See chapter 23 for details
Press NO
ENGINEER TESTS?
Press NO
Moves to next menu item
SYSTEM DIAGNOSTIC
FACILITIES
The system diagnostics are
available for all parts of the system,
including any remote power
supplies fitted.
The diagnostic resolution is:
VOLTS: 0.1v
CURRENT 0.01A
System voltage and current
at
End Station and at each individual
power supply.
(There are no current
readings on Euro-10/12).
System voltage
– at
each Keypad / Tag
Reader
Battery condition and charge current
at End Station or any remote
power supply (under development).
Output Diagnostics
for each output,
with voltage and system current
diagnostics.
Display zones
current status of all
zones connected to a single system
component, displayed in real time
iD Diagnostics
Slow scan mode
(including display of actual mid
voltage), line current, biscuit
diagnostic current
at End Station
and each Zone Expander
Calibration
calibrates End Station iD
output voltages, also calibration of
diagnostic reading of unit to
correspond with a calibrated meter.
Note: Certain parts of the
diagnostic readings from remote
‘intelligent’ power supplies are
NOT yet available.
With display showing
DIAGNOSTICS
Press YES
View PSUs?
Press YES
End Station PSU
13.75v 0.22A
Display shows diagnostic
readings for End Station power
supply in quiescent state.