Manual Euro-MERiDIAN
Chapter 13 Page 13 - 33
1. To identify the communicator
output channels to correspond to
the STU output numbers, refer to
table on page 11-15/16.
2. When programming ‘follow zone’
outputs (type 035), additional
options require selection, see page
25-1,2 for full details.
3. Output configuration for Slot-in
Digi-Modem is selected from
‘Programme Digi-Modem’ menu.
4. When a Set/Unset Tag Reader
is programmed as a ‘Ward
Controller’ the outputs will
automatically be programmed for
that Ward (see chapter 16).
5. A TMZ is programmed exactly as
for a Tag Reader, EXCEPT that
output 2 is FIXED as a loudspeaker
output – regardless of any
configuration allocated to it here.
To programme the areas for which
tones will be generated, see ‘Assign
Keypads and Tag Readers on 13-14.
Euro-44+ RELAY OUTPUT
This output (at terminals A) is
available only on Euro-44+ (and
above) End Stations. The output
is configured using jumper JP1
on the printed circuit board.
The options are:
Jumper at left
(linking pins 1-2)
Follows ES
output 3
Jumper at right
(linking pins 2-3)
System
watchdog
(xv) INTELLIGENT SETTING
LEVEL SETTING SYSTEMS
Setting the system in pattern
‘A’ will commence ‘intelligent
setting’ of the whole system,
with the exit tone at
‘intelligent’ volume level.
Activating the nominated zone
during exit time will cause the
system switch to pattern
‘
B.
’
AREA SETTING SYSTEMS
(Euro-44+ and above)
Setting the system with any code
including area B will initiate setting
the areas for which the code/tag is
valid, with the exit tone at
‘
intelligent
’
level.
Activating the nominated zone
during exit time will cause the
system to OMIT area B, and
‘
quick
-
set
’
the remaining areas.
NOTE: To be able to unset
successfully, a detector must be
sited to start entry time before
unsetting.
The 'intelligent' detector must be
sited to ensure that ALL potential
users of the system are correctly
detected. Some ' pet-immune'
detectors are NOT suitable.
ALL SYSTEMS
The nominated
‘
Intelligent
’
zone is
the one controlling access to the
area that is to be UNPROTECTED
when the system is set.
If an FX zone is triggered before
the nominated zone, the system