Manual Euro-MERiDIAN
Appendix A Page A - 5
INDICATIONS ASSOCIATED WITH ENGINEER MENU
Engineer
Access
Denied
Access to Engineer
menu NOT possible,
as system is not
fully unset.
Ensure that ALL areas are unset,
using suitable USER codes / Tags at
appropriate keypads / readers.
Check
Failed
Zone xxxx
Zone in fault on
attempting to exit
engineering
Applies to 24-hour tamper, or
other zone types that would
generate an alarm condition if
the system were returned to 'day'
mode.
Also applies to tamper fault on
other zone types.
Check for fault on zone, or isolate
in programming.
Error zone
areas not
accessible
A zone has been
programmed to an
area for which no
setting point is
valid to unset
It would therefore be impossible
to fully unset the system after a
tamper alarm on that zone.
Programming must be adjusted
before exit engineering.
Error some
areas
cannot be
unset
Setting points have
been programmed
such that it is
possible to set an
area, but not unset
it.
Programming must be adjusted
before exit engineering.