Castle Care-Tech Ltd. Engineering
Page 5 - 4 Chapter 5
AB
code at
A
keypad will
unset only A
B
code at
AB
keypad will
unset only B. etc.
The system will respond by
unsetting the resulting valid areas.
Keypad sounders respond only to
signals for areas they control.
It is essential that the system be
programmed such that all areas
that may be set can also be unset;
and that all areas to which zones
are allocated can be unset.
Notes: ‘Set’ and ‘Unset’ allocations for
individual setting points may differ
eg a bedroom keypad may be
programmed to
set
only the downstairs
area, but
unset
the entire system, etc.
If a multi-area code
without
the ‘flexi-
set’ attribute is used at an appropriate
keypad whilst part of the system is
set, the remaining valid area(s) will set,
UNLESS
entry time has started, in
which case the valid areas will unset.
From Software 3·1, the system will
always default to unsetting all areas
for which the code is valid.
f) LOCATED
IN
AREAS
When setting from a keypad /
reader located
IN
the area being
set, the programmed exit
mode/time will apply. W hen
setting an area from a keypad NOT
IN
that area, 5
-
second
quickset
exit mode will apply. This will NOT
apply to setting of area B as part
of a
Full
system set if
intelligent
setting
is enabled.
If a Set Point programmed as
IN
multiple areas is used, the highest
priority programmed for those
areas
Timed
lowest and
PTS
highest – will apply. Any other
areas being set will
Quickset.
Exit
volume level will always be the
highest applicable to area(s)
actually being set.
On entry, the system will allow the
highest entry time applicable to
areas to which the entry door is
allocated.
On entry, correct cancellation of
entry time will ONLY be possible if
the areas the keypad used is
‘located in’ exactly matches the
areas for which the entry route
zones are valid.
D: OMITTING ZONES
Zones to be omitted must have
the
omittable
attribute selected.
The omission may be done by:
(i)
24 hour tamper
’‘
day alarm,
and similar zone types may be
omitted during an unset period
from the Manager menu.
Readmission may be done from
the menu, or automatically when
the relevant area is next set.
(ii) During setting procedure, press
YES whilst
Unable to Set
is
displayed, or during the first 20
seconds of exit time, then enter
the number of the zones to be
omitted. If the
LEAVE OPEN
option is selected (in
SITE
OPTIONS
) a zone active at the time
of setting will be omitted just by
pressing
YES
whilst it is displayed.