MANUAL Euro-MERiDIAN
Chapter 23 Page 23 - 3
Testing
If live testing is conducted to a
suitable telephone, please bear
in mind that a delay in receipt
is likely to be a function of the
messaging service, rather than
an alarm system fault.
The Engineer Test menu
contains an option to ‘Test CHC
Communications’ that initiates
a call to the CHC.
The system will automatically
carry out a test call to the CHC
every two weeks. Castle Care-
Tech will contact the alarm
company in the event of this
call not being received.
Summary of Steps to Set
Up for SMS Text Message
Transmission
1
In
‘
Setup
Down-
loading
’
Select
Communications
as
‘
MODEM
’–
cannot be used in
‘RS-232’ mode
(see page 22-3)
2
In
‘
Setup
Digi/SMS
’
Select content
type(s).
Program mobile
number and
Network
(see page 23-4)
Program Account
Reference (see
page 23-5)
3
In
‘
Test
CHC
Communi
cations
’
Initiate test call
to CHC
(see page 23-6)
PROGRAMMING
PROCEDURE:
Within the ‘SET UP
DOWNLOADING’ menu, ensure
that ‘MODEM’ is enabled, as
shown on page 8, and then
scroll to:
SET UP
DIGI/SMS?
Press YES
Program Digi/SMS
Calls?
Press YES
Disable Digi/SMS
Yes [1]
Use
D
to select
‘
No [1]
’
NOTE: This option permits calling to
be disabled at any time (eg for
testing) without cancelling any
programmed settings.
Press YES
Program Digi/SMS
Call [1]
Select identity of call to be
programmed (1 to 4)
BE CAREFUL NOT TO
OVERWRITE ANY DIGI CALLS
ALREADY PROGRAMMED.
Press YES
Active?
Yes [1]
Use
D
to select
‘
No [0]
’
or
‘
Yes [1]
’
Note additional option when
programming Call numbers 2, 3
and 4
–
see at
!
Press YES