Programming Manual EURO
RINS1291-3 Page: 49
Test Siren?
To Test the Siren press the key.
All outputs programmed as either Siren or
Strobe will be tested. ‘Testing Siren’ will be
displayed. Press the key to stop the test.
‘Test Siren’ will be displayed, press the
key.
Do Battery Load Test?
To perform a Battery Load Test, press the
key. The Battery Load test will be
started. Once the Battery test has
completed, press the key, ‘Do Battery
Load Test’ will be displayed, press the
key.
Test Outputs?
This tests all the outputs on the control panel
(including outputs on ZEMs, Output Modules,
and ATE pins) To test the outputs press the
key. Select the Output type you would
like to test (see page 35 for the output
types) and press the key.
All outputs programmed as the type selected
will be active. Press the key. The
outputs will switch off. Repeat for other
output types as required. Press the key.
‘Test outputs’ will be displayed. Press the
key. You will be returned to the Engineer
Menu.
Test CHC Communications
If you are using SMS, you need to send a
test signal to the Castle Host Computer.
Press . ‘Test Complete’ will be displayed
after a couple of minutes. Press
Test SIA/CID Communications
If you would like to test SIA or Contact ID
communications, press and a test signal
will be sent to the ARC. Press
Comentarios a estos manuales