Alarm Responses
Using the and keys, scroll to
‘ALARM RESPONSES?’
Press the key
Silent 1
st
Alarm
Enter : for Never
Enter : for Confirmed
Press the key
Disable Confirm On Entry
Enter : for No
Enter : for Yes.
Leave as NO for use with DD243 clause
6.4.5 or Change to YES for use with
DD243 clauses 6.4.3 / 6.44.
Press the key
Inputs to Confirm After Entry
Enter the number of inputs to Confirm after
the Entry. (Leave at 2 to comply with
DD243). Press the key
Area Starts
Enter : for Keypads
Enter : for Internal Sounders
Enter : for Sirens Only
Enter : for Digi
Enter : for Confirm
Press the key. Repeat for Area Stops and
then repeat the above for each other Area
and also for Fire, Gas, HU and Day alarms
You will be returned to the Engineer Menu