4.18 Engineer Reset Options
The Engineer Reset Options are used so that once an alarm has occurred; the EURO system
can only be reset by an engineer code, anti code or red care reset from the alarm receiving
centre.
Option Function
Engineer
Restore of
Intruder
Following an intruder alarm, an engineer must reset the system before it
can be used again. Please select ‘UK Intruder’ to enable this, ‘Secure
Intruder’ should not be used. This will not interfere with the generation of
an emergency alarm. The default setting is No.
Engineer
Restore of HU
Following a Hold Up, Input HU or Duress alarm, an engineer must reset
the system before it can be used again. This will not interfere with the
generation of a Fire or Gas (emergency) alarm. The default setting is
No.
Engineer
Restore of
Tamper
Following a Tamper alarm, an engineer must reset the system before it
can be used again. This will not interfere with the generation of an
emergency alarm. The default setting is Yes*
Engineer
Restore of Soak
In the event of an input with the ‘soak’ attribute triggering whilst the
system is set, the system must be reset by an engineer before it can be
used again. This will not interfere with the generation of an emergency
alarm. The default setting is No.
Engineer
Restore of
Confirmed
Following a confirmed alarm, an engineer must reset the system before it
can be used again. The default setting is No.
Engineer
Restore of
Faults
If selected, only an engineers code will be able to reset the following
faults: ATE telecom fail, Modem fail, ATE single path fail, Telecom line
fail, Battery disconnect, Batt charge, Batt load, Excessive charge, Battery
critical, Device fail. The default setting is No.
Anti Code
Restore
Enables the system to display an anti-code whilst awaiting an Engineer
reset, which can be used to generate a special reset code. The default
setting is No.
*The default setting is set as No for the EURO 28.
Engineer Restore Options
Using the and keys, scroll to
‘ENGINEER RESTORE OPTIONS?’
Press the key
Eng Restore Int
Enter : for No
Enter : for UK Intruder
Press the key.
Repeat the above options for the restores:
Tamper, Soak, Confirmed, and Faults
(Enter : for No, : for Yes)
Press the key.