Programming Manual EURO
RINS1291-3 Page: 15
Number & Type Operation
11 PTS
Active during exit time to complete Setting procedure
No audible or communicator response.
Note: May be used to act as ‘doorbell’ by use of ‘chime’ attribute.
12 Switcher
Active at all times. No audible or communicator response
Triggers associated output or switches other equipment
13 Day Alarm*
When set: Audible Response: Full.
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals
When unset: Audible Response: Programmable.
Communicator: ‘Day Alarm’ signal
15
Ward
Control*
Input is allocated by system software and cannot be reprogrammed to
a different type, though relevant attributes may be adjusted.
16 Fault
Active when unset. Audible Response: Graduated internally
Triggers ‘Global Fault 1’ outputs if the system is set.
Triggers ‘Global Fault 2’ output if the system is set/unset.
17
Closure
Supervision
Active during Setting procedure. No audible or communicator
response. Prevents system being set whilst active
18
Shunt
Input*
Active at all times. No audible or communicator response
Accepts input from keyswitch (or equivalent) to shunt the inputs
assigned to it. Associated outputs are available. After 10 seconds the
detectors in the shunt list will be active. See page: 19
19
Unset
Input*
Active when set. Accepts input from keyswitch (or equivalent) to
Unset the Area/Level set assigned to it.
20
Keyswitch
Latched
Accepts input from keyswitch (or equivalent) to Set/Unset the Set
modes assigned to it. Setting includes normal exit time, etc. Requires
latching action switch
21
Entry Shock
Input
Active when system set. Works in conjunction with EE input type for
detection of forced entry. See page 16 for details.
22
Input Line
Fail
Active when fail. Will give a line fault alarm, and will signal telecom
line fault signal on expiry of line fault timer. Works in conjunction with
CCTV input.
23
Keyswitch
Pulsed
Accepts input from keyswitch (or equivalent) to Set/Unset the Set
modes assigned to it. Requires momentary action switch to toggle
set/unset state.
29 Interior
This will work the same as an Intruder type input, the only difference is
that when CID reporting is programmed then any inputs that are
programmed as Interior will report CID event 132.
32 Flood
This input type will work as a 24 hr input , any inputs that are
programmed for Flood will activate the external siren and will report
CID event 113.
39 CCTV
Active at all times. No audible or communicator response
If the input line fail is active, the system will signal CID/SIA events for
perimeter alarm and the CCTV input will open.
40 Perimeter
This will work the same as an Intruder type input, the only difference is
that when CID reporting is programmed then any inputs that are
programmed as Perimeter will report CID event 131.
41 Keybox
This input type will work similar to a switcher input, it does not trigger
an alarm but will report CID event 250 and is also a useful input type
when an output is required to to follow the Keybox type input.
42 Medical
This is a 24 Hr type input it will activate the external sounder and
report a CID event 100.
NOTES: ‘Part Set’ refers to any combination other than all available Areas