Programming Manual EURO
RINS1291-3 Page: 23
4.7.5 *Access Control/Door Entry Control
*This feature is not available on the EURO 28.
The following programming shows how to set up the Access Control facility if you are using it.
Also the same programming process applies to ‘Door Entry Control’ which allows a tag reader
to control an entry point.
Assign Keypads/Readers
Using the and keys, scroll to
‘ASSIGN KEYPADS/READERS?
Press the key
Address
Enter the address of the keypad/reader you
wish to assign. Press the key
Type
Enter : for Reader. Press the key
Reader Is
Enter : for Access Control
Or Enter : for Entry Control
Press the key
Enter the Lock Open Time (max: 250
seconds). This is the time the door release is
going to be active when a valid tag’s
presented. Press the key.
Enter the Door Open Time (max: 250
seconds). This is the time the door is allowed
to be open before triggering an alarm. Press
the key.
Enter the input number to monitor the
chosen door. Please note that this must be
selected for the door monitoring to function.
Entering ‘999’ disables the monitoring for
this door.
To enter a personal name for the access
control (based on its address), press the
key. Use the text programming to enter this,
see page: 9. Press the key, you will be
returned to the engineer menu.