Programming Manual EURO
RINS1291-3 Page: 17
*Special Log
Forces a log entry when the input is opened or closed, even when an alarm
does not result. May be selected to apply when a system is set, when unset,
or always.
*Paired
Input
For use in Grade 3 iD systems (or EoL inputs on peripheral devices fitted
software prior to version 5). Select to ‘YES’ for each of the two biscuits
acting as the input. Fault Input: Select to ‘YES’ for the biscuit acting as the
‘fault & anti-mask’ Paired With: For both biscuits enter the input number
with which each is paired.
Confirm
Group
If one or more inputs are selected within the same confirm group, all
confirmed signals will be disabled. If confirm group is selected as ‘00’ the
inputs are not part of any group. If inputs are allocated to group 99 they will
generate an alarm that results in an intruder (unconfirmed) signal to an ARC.
They will not under any circumstances generate a confirmed signal,
regardless of which group the input that selected the ‘unconfirmed’ alarm is
allocated to.
*These are not available on the EURO 28. All attributes are disabled at default.
Any input may be programmed with any combination of these attributes, except where stated.
4.6.5 Masking Response
When unset, a masking event will generate an audible “alert” that requires response in the
normal way. There will be NO signal transmitted to the ARC. When set, a masking event will
generate a normal ‘intrusion’ response including “intruder” or “unconfirmed” output, but will
NOT result in a confirmed alarm if paired with a normal activation of the same detector. This
harmonises with the requirement of EN50131-1 cause 8.4.5 and the insurer’s preference
expressed in BSIA Form 171.
4.6.6 Automatic Inhibit of Inputs
Inputs may be automatically inhibited (omitted) at the time of reinstatement at the end of
confirmation time. The number of times that this takes place is controlled by the “Re-Arm
Number” in the timers section. See page: 27.
Change Inputs
Using the and keys, scroll to
CHANGE INPUTS?’. Press the key
Input
Select the input number you wish to program
and press the key.
Input Type
Select the input type (See the ‘input types’
table – Page: 14) by using either the
numeric code or the andkeys.
Press the key.