Started Manual Castle Care-Tech Ltd
5·00 Page 13
Mount all detectors in the
required locations, and wire
them to the iD bus in any parallel
configuration
parallel, spur or
star
as above.
NORMALLY OPEN DETECTORS
should be connected in the same
way, with the Normally Open
attribute selected when
programming the input.
For input number identification,
refer page 27,28.
iD LINE TERMINATION
Each cable run should be
terminated with a 0.01µF
capacitor connected between iD
+ and - (yellow and blue) at the
last biscuit
Reminders for successful
installation of an iD system:
1. Ensure that all biscuits are
correctly connected
2. Do not mix iD and iD Plus
biscuits
3. Ensure that safe wiring
distances are not exceeded and
cable runs are correctly
terminated (0.01µF capacitor).
4. Ensure that all biscuits are
wired directly to the detector
5. Ensure that cabling
specifications are carefully
followed (see page 8).
6. Ensure that the resistance
measurements are correctly
checked and recorded.
If you are not familiar with iD
wiring, please request Technical
Note “Installing iD Systems” for
additional information
.
Note on Programming Biscuits
for Grade 3 systems:
Paired Input?
Yes [1]
When programming both
biscuit 1 and 2 (see page 12),
set this to yes.
Fault Input?
No [0]
If programming biscuit 2,
the biscuit connected to the
mask/fault terminals of the
detector, set this to ‘yes’,
otherwise leave at ‘no’.
Paired With?
Enter the input number of
the biscuit you are pairing
with (for each input of the
pair), e.g. if programming
biscuit 2, enter the input
number of biscuit 1.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 14 Software
7. WIRING OUTPUTS
When wiring outputs, do not exceed the maximum rating
for individual outputs, or the system power supply.
SAB Connections
OUTPUT RATING
Strobe and Siren Outputs are
rated for 800mA each. Note
that the 'Hold Off' fuse is rated
as 800mA.
Ensure that the system
power supply is not
overloaded.
Other End Station Outputs
Current Available
:
Speaker:
500mA
Output 3:
100mA
Output 4:
100mA
NOTE: Output 3 may also be
used at relay terminals ‘A’ on
Euro-G3+. Select jumper JP1
at left, linking pins 1 and 2
Current Available
:
O/p 1 (siren):
800mA
O/p 2 (strobe):
800mA
Hold Off:
800mA
Note
tamper return
is NEGATIVE.