CASTLE Meridian Especificaciones Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
Started Manual Castle Care-Tech Ltd
5·00 Page 3
2. SPECIFICATIONS
A: ELECTRICAL SPECIFICATIONS
Mains Supply 230v AC Max 150mA
Fuse 250mA slow blow
Power Supplies 13·75v DC. Current rating as below.
Please ensure that power supply capacity is
adequate for the proposed system load.
Battery Fuse 1·5A quick blow (G2 endstation)
3·15A quick blow (G3plus Endstation)
Supply out Fuses 800mA quick blow
Standby Battery 17Ah
Ratings for all Power Supplies
Specified battery: 12v 17Ahr Lead-Acid
PSU Electrical Capability: G2 units: 1.5 A
G3 units & intelligent PSU: 2.5 A
PSU Rating (EN50131-6): Grade 1 Systems: 1.25 A
Grade 2 Systems: 1.0 A
Grade 3 systems: 700 mA
Note: When Intelligent PSU is used for Access Control purposes, it is
suitable for a maximum short-term loading of 2A for up to 15 seconds.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 4 Software
B: SYSTEM SPECIFICATIONS
Euro
-
G2 iD G2 EoL MSX-
44 iD
MSX-
44 EoL
G3+
iD
G3+
EoL
MSX-
134
iD
MSX-
134
EoL
MSX-
256
iD
MSX-
256
EoL
Inputs (max)
24 16 44 74 134 256
ZEM Inputs
1 x 8 1 x 8 1 x 8 4 x 8 1 x 30 7 x 8 3 x 30 14 x 8 7 x 30 29 x 8
Set points
(max) §
4 8 8 30 30
of which, max
keypads:
4 8 8 16 16
Other Devices
Max:
3 7 7 29 29
Level Sets
4 4 4 8 14
Full Areas
- 4 4 8 14
Wards (max)
- 7 7 29 29
Shunts
- 16 32 64 128
User/Managers
12 50 100 230 500
Duress/Guards
10 20 20 20 20
Logs
750 2000 2000 2000 2500
Output Mods
1 2 4 8 8
§
Includes keypads, tag readers, access control units and TMZs
Vista de pagina 1
1 2 3 4 5 6 7 ... 26 27

Comentarios a estos manuales

Sin comentarios