Started Manual Castle Care-Tech Ltd
5·00 Page 5
3. END STATION TERMINAL LAYOUT
Euro-G2 iD and EoL
P20
P1
Slot for DigiModem
Slot for MSX Card
NVM2 NVM1
F1
F2
F5
F6
F4
STU
Connector
RESET
24LC256
H1
H2
H3
H4
H5
H6
H7
H8
E1/H9
E2/H10
H11
E3/H12
E4/H13
D1
D2
D3
D4
C1
C2
C1
C3
B1
B2
B3
B4
B5
TA
TB
TC
TE
TD
G1
G2
G3
If MSX-134 or 256 card is used
additional 24LC256 NVM is
required in the NVM2 slot.
Terminal Allocations:
D RS.485
1 0v
2 +12v
3
‘
A
’
4
‘
B
’
E iD bus
(
Euro-G2 iD only
)
1 0v
2 +12v
Black
Red
(H11 is NOT used)
G AC input:
1 Mains earth
2
-
3 Transformer
B SAB:
1 O/p 2
–
2 O/p 1
–
3 Tamp Ret
4 HO
–
5 HO +
C Outputs:
1 Speaker
–
2 +12v
3 O/p 3
–
3 Line
–
4 Line
+
J Not used
Blue
Yellow
H EoL Inputs
(
Euro-G2 EoL
only
)
1 Input 1
2 Common
3 Input 2
6 Input 3
7 Common
8 Input 4
11 Input 5
12 Common
13 Input 6
4,9 0v
5,10 +12v
T Telecomms -
see info
supplied with DigiModem
Fuse Allocations
:
F1: +12v at terminals E or H 800mA
F2: +12v at terminals D 800mA
F4: +12v BATTERY 1.5 Amp
F5: +12v at terminals C 800mA
F6: +12v at terminals B 800mA
Line ‘A’ in
Line ‘B’ in
Line ‘A’ out
Line ‘B’ out
Telecom Ground
Earth
C
Input
}
Started Manual Castle Care-Tech Ltd
5·00 Page 6
Euro-G3 PLUS
1
2
3
4
5
6
7
8
STU/DigiCom
Outputs
Euro-MERiDIAN
9
10
11
12
13
14
15
16
F1
F5 F6
NVM
NVM
Socket for
additional NVM
(MSX-134 & 256)
P1 P20
Slot for MSX Card/RS232 Card
Slot for DigiModem
F2
F3
F4
A1
A2
A3
B1
B2
B3
B4
B5
C1
C2
C3
C4
C5
D1
D2
D3
D4
E1
E2
E3
E4
G1
G2
G3
Earth
AC
Input
{
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
TA
TB
TC
TD
TE
J1
J2
J3
RESET
JP1 (relay)
Engineer
Keypad
Connector
24LC256
24LC256
Tam pe r Sw it ch
Jumper
P18
Terminal Allocations:
A Relay
(see p.21)
1 C Contact
2 NC Contact
3 NO Contact
B SAB:
1 O/p 2
–
2 O/p 1
–
3 Tamp Ret
4 HO
–
5 HO +
C Outputs:
1 Speaker
-
2 +12v
3 O/p 3
–
4 0v
5 O/p 4 +
D RS.485
1 0v
2 +12v
3
‘
A
’
4
‘
B
’
E iD bus
1 0v black
2 +12v red
3 Line
– blue
4 Line + yellow
G AC Input
H EoL Zones
1 Input 1
2 Common
3 Input 2
6 Input 3
7 Common
8 Input 4
11 Input 5
12 Common
13 Input 6
4,9 0v
5,10 +12v
T Telecomms
- see info
supplied with DigiModem
Fuse Allocations
F1 (LED O4): +12v at terminals H 800mA
F2 (LED O1): +12v at terminals D 800mA
F3 (LED O5): +12v at terminals E 800mA
F4 (LED O6): +12v BATTERY 3.15Amp
F5 (LED O3): +12v at terminals C 800mA
F6 (LED O2): +12v at terminals B 800mA
Indications:
LED pulsing indicates communications normal
LED flashing at even on/off rate indicates fuse
overload
LED steady indicates fuse blown
Comentarios a estos manuales