Started Manual Castle Care-Tech Ltd.
3.00 Page 9
5. INSTALLING END STATION and KEYPADS
THE END STATION
Mount the End Station
securely using 4 fixing screws.
MAINS
ELECTRICITY IS
DANGEROUS
The mains connection to the
End Station should comply
with BS.7671, and be made by
a competent electrician from
the consumer unit or
unswitched fused spur.
The mains cable
should be routed
through the inlet
adjacent to the
connector block. Do
NOT use an alternative
inlet, or loop the
mains wire within the
housing, to avoid the
EMC performance
being degraded.
CAUTION
:
Disconnect the mains supply before removing the cover.
Never add equipment to the system with power applied.
KEYPADS and TAG READERS:
Similarly, mount the Keypads and
Tag Readers as required.
NOTE: Keypads and Tag Readers
should NOT be mounted on a
metal surface, or within 0·6
metres of each other, to prevent
degradation of tag response.
Tag Readers, Access Control
Points and TMZs must be
addressed before being powered
up. These must be allocated in the
same number series.
Address 00 is always reserved for
the principal Keypad.
Address Switch 1 Switch 2 Switch 4
0 Closed
Closed Closed
1
OPEN
Closed Closed
2 Closed
OPEN
Closed
3
OPEN OPEN
Closed
4 Closed Closed
OPEN
5
OPEN
Closed
OPEN
6 Closed
OPEN OPEN
7
OPEN OPEN OPEN
Switch 8 should be CLOSED.
The address switches on TMZs
and ZEMs work slightly
differently. Switches should be
pulled towards the numbers
printed on the PCB to add up to
the address required. Example
below shows address 01.
N E L
Keypads are addressed in software
(see page 21) in the SAME number
sequence (0-x) as Tag Readers, etc.
Zone Expander Modules and Output
Modules are addressed in the same
way, but in independent number
sequences (0-x).
Fuse
250mA
Started Manual Castle Care-Tech Ltd
5·00 Page 10
WIRING Keypads and Tag
Readers
These require a minimum 4-core
connection. 6-cores is preferred,
with the supply connections
(D1,2) doubled up to minimise
voltage drop. Twisted pair cable
should be used.
Do NOT double up the
communications pair (D3,4)
under any circumstances.
Simply connect terminal D1 to
D1, D2 to D2, etc.
Devices should be wired in
sequence (daisy-chained) rather
than starred or spurred.
In the event of a keypad or tag
reader being located more than
100 metres from the End Station,
or if the supply voltage at the
device falls to 11 volts or less, we
recommend that it be powered
from a local power supply.
The supplied 470-ohm resistors
should be fitted between
terminals D3 and D4 at the device
at each end of the RS-485
network, as below:
Remember to put the 470 resistors at each
end of the RS485 data BUS. (If the overall cable
length is less than 20m the resistors should not
be used).
Colour code 470 : Brown / Red / Brown
470 resistor — connect to last
item at each end of network