Started Manual Castle Care-Tech Ltd
5·00 Page 39
VOLUME LEVELS
This applies to the system
loudspeaker
output
levels
generated at Keypads are
programmed individually.
Each system tone may be
programmed to a pre
-
set volume
level, on a scale of 0 to 7.
The default levels are:
Intelligent set 2
Chime tone 3
Exit tones 3
Entry tones 4
Alert tone (tamper) 6
Alarm tones 7
NOTE: Level 1 is SILENT with an audible
chime (at volume level set for chime)
at the
end of settle time. Chime present at all
volume levels except 0. This may be used in
conjunction with Site Option “E/E Keypads
Only” when ‘Silent Set’ is required.
ALARM RESPONSES
Silent 1
st
Alarm
This prevents all system sounders from
becoming live until an alarm has been
'confirmed' - eg to prevent noise
interfering with audio confirmation
equipment. Only applies after panel
has been set for 3 minutes.
Disable Confirmation on entry
Used with a suitable FX, Unset or
Keyswitch input to disable all
sequential confirmation operation to
satisfy relevant options in DD243:2004.
Inputs to confirm after entry
Accepts 1 or 2 inputs to trigger after
expiration of entry time to qualify as
'sequentially confirmed' alarm.
NOTE: ONLY THE "2" SETTING
COMPLIES WITH DD243:2004.
Each area alarm response
may be
programmed with the option of
graduated
functions, as can
Day Alarm,
Fire,
Gas
and
HU
alarms. Graduation can
be between 'Keypads,' 'Internal Sounders,'
'Sirens only,' 'Digi' and 'Confirm.'
The following options are available for each:
Starts at _ _ _ _
Insert initial alarm level
Stops at _ _ _ _
Insert final alarm level
The response may thus be set to
graduate from keypad sounders to
internal sounders to sirens to digi
(remote signalling) to confirmed,
with 15 seconds at each level before
the next step.
NOTE: An additional upgrade level is
available if using Area setting.
To comply with EN50131, ‘Day
Alarm’ must be set to ‘Stop’ no
higher than Sirens Only.
PROGRAMMING STEPS:
With the display showing
ALARM RESPONSE?
Press YES
Area A Starts at
Keypads [1]
Use
D
to select from
Keypads [0],
Int Sounders [1],
Siren only [2]
and
Digi [3]
and press YES,
Area A stops at
Confirm [4]
Use
D
to select from
Keypads
[0],
Int Sounders [1],
Siren only
[2]
Digi [3]
or 'Confirm [4] and
press YES
Repeat for other areas, etc.
ALARM RESPONSE?
Press NO to move to next menu
item
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 40 Software
PROGRAMMING OUTPUTS
Any output type may be
programmed to any of the
system outputs.
The most frequently used output
types are summarised below.
Additional output types are
available for advanced use see
full Engineering Manual.
Outputs MUST be used within
their rated capacity.
Please note particularly the
differences between Hold Up, PA
and Duress. For general use the
default ‘HOLD UP’ should be used.
NOTE: To identify the STU output
numbers that correspond to the
communicator output pins/loom
colours, refer to table on pages 17,
18 & 19.
Type Default Active Restore
0000 Not Used Default setting except where shown
0001 Fire ATE 1 At Alarm When valid code entered
0002 Hold Up Any - At any HU/Duress alarm When valid code entered
0003 Intruder
ANY
- At alarm, while system
set
At first valid code entry
0004 Final Set ALL ATE 4 When system is FULLY
set
At code entry to unset
0005
Misoperation
ANY
(Abort)
When system silenced
after any
intruder
output triggered
After 2 minutes
0006 Confirmed
ANY
ATE 6 When alarm is
sequentially confirmed
– see page 42
At next code entry
0007 Tamper Any ATE 5 Any tamper alarm At code entry to silence
0009 HU Device ANY ATE 2
At Alarm on a
HU device
(NOT Duress)
When valid code entered
NOTE: This output type responds ONLY to devices
wired into HU Inputs, NOT Duress Codes or 2-key PA
0010 Gas
-
At Alarm When valid code entered
0014 Siren
ANY
ES 1 When alarm live When alarm silenced, or when
Siren timer expires
0016 Strobe
ANY
ES 2 When alarm live When alarm silenced, or when
Strobe timer expires
0017 Omit Rearm
Any
ATE 7 At rearm at end of
confirm time, if zone in
fault isolated
When system unset
0018 Unconfirmed ATE3 Any tamper or intruder
alarm when system set.
At code entry to silence OR at
rearm (re-instatement) at end
of 'confirm' time.