6. WIRING DETECTORS
End of Line Wiring
Grade 2 sytems
Resistor colour code:
2K2 – Red / Red / Red / Gold
4K7 – Yellow / Purple / Red / Gold
The 2K2 resistor MUST be
located at the furthest point on
the wiring circuit, or the wiring
security it provides will be lost.
Grade 3 Systems
Resistor colour code:
2K2 – Red / Red / Red / Gold
4K7 – Yellow / Purple / Red / Gold
6K8 – Blue / Grey / Red / Gold
12K – Brown / Red / Red / Gold
A link must be fitted between
the alarm and fault terminals as
shown right. The 2K2 resistor
MUST be located at the furthest
point on the wiring circuit, or
the wiring security it provides
will be lost.
Please select the correct wiring
configuration from those shown
on this page which match the
terminals in your detector.
tamper alarm fault
+ -
2K2
4K7
To panel zone terminals
tamper alarm fault
+ -
2K2
4K7
To panel zone terminals
6K8
Tamper
larm Fault
+ -
2K2
4K7
To panel zone terminals
6K8
Mask
12K
Tamper
larm Mask
+ -
2K2
4K7
To panel zone terminals
12K
Keypad/TMZ Input wiring:
1: Wire between K1 & K3
2: Wire between K1 & K4
Endstation Input Wiring:
1: Wire between H1 & H2
2: Wire between H3 & H2
3: Wire between H6 & H7
4: Wire between H8 & H7
5: Wire between H11 & H12
6: Wire between H13 & H12
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 12 Software
iD PLUS WIRING
Grade 2 systems
Grade 3 Systems
If “MASKING” terminals not present on detector, link ‘biscuit 2’ yellow
wire direct to line.
If “FAULT” terminals not present, link ‘biscuit 2’ blue direct to line
and short ‘biscuit 2’ white to blue.
NORMALLY OPEN DETECTORS should be connected in the same way, with
the ‘Normally Open’ attribute selected when programming the zone.
tamper alarm fault
+ -
To panel zone terminals
igure 1
blue
white
yellow
yellow
blue
To panel zone terminals
Tamper
larm Fault
+ -
yellow
blue
bl blw
y
y
w
Biscuit 1
Mask
Biscuit 2
To panel zone terminals
Tamper
larm
yellow
blue
bl bl w
y
y
w
Biscuit 1
Mask
Biscuit 2
Blue wire (iD negative)
should connect to
endstation terminal E3.
ellow wire (iD positive)
should connect to
endstation terminal E4.