Started Manual Castle Care-Tech Ltd
5·00 Page 37
PROGRAMMING CODES and
TAGS
Codes may be 4-, 5- or 6-digit (It is
preferable to avoid mixing
different length codes on the
same system), or proximity Tags.
There is an option to only allow
5-digit codes for Grade 3
purposes. The security patterns
valid for each may be
programmed.
CODE TYPES and NUMBERS
Product: User/Manager
Codes
Duress/Guard
Codes
Euro-G2 12 10
MSX-44 50 20
Euro-G3+ 100 20
MSX-134 230 20
MSX-256 500 20
Plus Master Manager and Engineer
codes
IMPORTANT NOTE:
The Engineer can programme
ONLY Engineer, Master
Manager, Duress and Guard
Codes.
Manager and User codes must
be programmed through the
MANAGER menu.
Engineer and Master Manager
Codes cannot be deleted.
Tags programmed as Manager
will not enter Manager Menu
from a Tag reader.
CODE CAPABILITIES
Type Functions
Set and Unset System
only
USER
Default
Also for Access
Control and Ward
Control functions
MANAGER
Set and Unset System
Also access to
Manager menu
functions
Program
by
MASTER
MANAGER
Default
2222
Access to Manager
menu functions only.
Program
by
Manager
OR
Engineer
ENGINEER
Default
1111
Access to all
Engineering
functions, also
set/unset system for
test purposes.
DURESS Unset System,
generating silent
‘
Duress
’
or
‘
Hold Up
’
signal
GUARD
Unset system, but
only after an alarm,
provided alarm has
been active for a
minimum time
(programmable).
Also Set System
An output type is
available to signal
whenever this code
is used.
Program
by
ENGINEER
only.
A site option “Restrict PIN use” is
available so that only TAGs may
be used during entry time.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 38 Software
PROGRAMMING STEPS:
With the display showing
CHANGE CODES?
Press YES
5 digit PINS?
No [0]
Use
B
and
D
keys to select
whether you need to restrict all
Pin-codes to 5 digits (required
for grade 3 installations)
Change Duress
Codes?
Press YES
User Number
[01]
Use number keys to select code
to be changed
Press YES
Enter User Code
[ ]
Use number keys to enter new
code, or present Tag to reader to
programme this.
Display shows [******] if a code
or tag is already allocated: enter
replacement code/tag, or press
C
to delete.
Engineer and Master Mana
e
Codes cannot be deleted.
Press YES
Code Type
Duress [2]
Use
D
to select between Duress
[2] and Guard Code [3]
User and Manager codes can be
programmed
only from the
Manager menu.
Press YES
UserAreas (Parts)
[ABCD]
Use keys to select Security
Patterns the code is to be valid
for. Whilst this is being done, the
‘
ABCD
’
keys will be illuminated to
reflect the choice made.
Press YES
User Set Options
Unset/Set [0]
Use
D
to select between
Unset/Set [0], Unset only [1], Set
only [2] and None [3]
Press YES
Flexiset
No [0]
Select as required
Press YES
User Name
_
Enter text, as described on
page 23.
Press YES
User Number
[01]
Repeat this procedure for
additional codes, and for
Change Master
Manager Code?
Change Engineer
Code?