Page:12 Castle Care-Tech
C
onnections
Double Pole
Input Wiring
+12V GND
Y
G
R Y
G
B R Y
G
B R Y
G
B
W W W
Blu Blu Blu
Terminal Block (inside
control panel)
Example cable
wiring
R = Red
B = Black
Y = Yellow
G = Green
This link
should be OFF
This link
should be OFF
Example cable
wiring
W = White
Blu = Blue
Terminal Block (inside
control panel)
+12V GND
+12V GND
ALARM TAMPER
+AUX-
Input 3
Detector
ALARM TAMPER
+AUX-
Input 4
Detector
ALARM TAMPER
+AUX-
Input 5
Detector
ALARM TAMPER
+AUX-
Input 3
Detector
ALARM TAMPER
+AUX-
Input 4
Detector
ALARM TAMPER
+AUX-
Input 5
Detector
BELL
BELL
BUS
BUS
BATTERY
BATTERY
AUX
AUX
PGM AUX+ SPK STB BELL TR B- B+
PGM AUX+ SPK STB BELL TR B- B+
Spare N/C Contact
Input 2
Door Contact
Remove for DP
Remove for DP
Z1 COM Z2 COM +12V Z3 COM Z4 Z5 COM Z6 COM +12V Z7 COM Z8 Z9 COM Z10 D1- D2+ D3 D4 - BAT + GND
Z1 COM Z2 COM +12V Z3 COM Z4 Z5 COM Z6 COM +12V Z7 COM Z8 Z9 COM Z10 D1- D2+ D3 D4 - BAT + GND
+12V GND
Y
G
R Y
G
B R Y
G
B R Y
G
B
W W W
Blu Blu Blu
Terminal Block (inside
control panel)
Example cable
wiring
R = Red
B = Black
Y = Yellow
G = Green
This link
should be OFF
This link
should be OFF
Example cable
wiring
W = White
Blu = Blue
Terminal Block (inside
control panel)
+12V GND
+12V GND
ALARM TAMPER
+AUX-
Input 3
Detector
ALARM TAMPER
+AUX-
Input 4
Detector
ALARM TAMPER
+AUX-
Input 5
Detector
ALARM TAMPER
+AUX-
Input 3
Detector
ALARM TAMPER
+AUX-
Input 4
Detector
ALARM TAMPER
+AUX-
Input 5
Detector
BELL
BELL
BUS
BUS
BATTERY
BATTERY
AUX
AUX
PGM AUX+ SPK STB BELL TR B- B+
PGM AUX+ SPK STB BELL TR B- B+
Spare N/C Contact
Input 2
Door Contact
Remove for DP
Remove for DP
Z1 COM Z2 COM +12V Z3 COM Z4 Z5 COM Z6 COM +12V Z7 COM Z8 Z9 COM Z10 D1- D2+ D3 D4 - BAT + GND
Z1 COM Z2 COM +12V Z3 COM Z4 Z5 COM Z6 COM +12V Z7 COM Z8 Z9 COM Z10 D1- D2+ D3 D4 - BAT + GND
If double pole is used, the link above input 1 (shown below) needs to be open.
Double pole requires no resistors, but it requires a dedicated tamper circuit
(When a clean start 2002 is performed, input 1 is defaulted as tamper).
The rst diagram below shows the connection of door contacts/detectors to the
EURO mini, the second diagram shows how the tamper circuits of each detector
should be connected. The diagrams are split for clearer wiring connections.
Please note that any ‘terminal blocks’ used should be located inside the control
panel.
Double Pole - Alarm Connections
Double Pole - Tamper Connections